22 CHAPTER 2 CONNECTING POWER AND SURGE
Smart
Sensor
Main trac cabinet
Pole-
mount
box
Earth groundEarth ground
120
VAC
Figure 2.2 – Underground Cable Run
Wiring the Click 200
ere are two cables that may be used with your sensor, the 8-conductor cable and the
9-conductor cable. Which one you use is based largely on the connector on your SmartSen-
sor HD—that is, the connector where the cable will be plugged into the sensor.
ere are two dierent connectors that may be found on a SmartSensor HD:
e 10-pin connector is used with the SmartSensor HD. It currently only comes in-
stalled on the 8-conductor cable.
e 26-pin connector is used with SmartSensor HD Legacy and retrotted HDs. It can
be installed on the 8-conductor cable or the old 9-conductor cable.
Note
There may be compatibility issues if you use a 8-conductor/26-pin connector cable
with a SmartSensor HD that was manufactured in or before 2008. Contact Wavetro-
nix Technical Services for details and assistance.
e wiring for these two cables is almost identical; the dierences are pointed out on the
following page.
Note
If you have an underground cable run that stretches more than 600 ft (182.9 m), you will
likely need to use a dierent cable; in that case the colors won't match the figure below.