Wavetronix Command DataView (CMD-DV) - User Guide Manuel d'utilisateur Page 51

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 106
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 50
50 CHAPTER 5 WORKBOOKS PAGE
collapsed by clicking on the node.
Update Properties – Refreshes lter properties updating changed values.
e individual lters and their properties are outlined below:
Consecutive Zero Volumes – Checks the volume counts for each data record. Flags
data if the number of consecutive zero volume records is equal to or greater than the
set value; the default value is eight.
Volume Reality Check – Checks each full day of data within the workbook to see
whether any data between 1 a.m. and 2 a.m. has a higher volume than the data from 1
p.m. to 2 p.m. indicating either awed data or an abnormal event.
Missing Intervals – Flags all missing data records.
Out of Bounds – Checks the given data value (Volume, Speed or Occupancy) against a
comparable value set in the Value eld. e Operator eld can be set to adjust the type
of comparison performed: greater than, less than, equal or not equal. Data is agged if
the given data value for a data record meets the comparison criteria for the lter. e
Auto Adjust Value can be used either to provide a suggested change to the data (when
the lter is run in Flag Items mode) or to automatically edit the data to the given value
(in Auto-Fix mode).
Over Speed – Checks the speed value for each data record, agging it if the speed is
above the given Speed value. e Auto Adjust Speed eld can be used either to pro-
vide a suggested change to the speed (when the lter is run in Flag Items mode) or to
automatically edit the speed to the given value (in Auto-Fix mode).
Repeated Values – Checks the given data value (Speed, Volume or Occupancy) for
each data record for multiple sequential entries that are the same value, indicating
potentially invalid or awed data. Congure the number of sequential entries in the
Repeated Intervals eld. e Auto Adjust Value can be used either to provide a sug-
gested change to the data (when the lter is run in Flag Items mode) or automatically
edit all sequential data records to the given value (in Auto-Fix mode).
To run one or more lters aer all properties have been set, click the Run Selected Filters
button. A sub-window will pop up listing the lter properties (see Figure 5.6).
Figure 5.6 – Run Data Filters Sub-window
It is not necessary to remain on the lter page while this operation is run—the DataView
system will run the lters and update the data in the workbook when completed. In cases
Vue de la page 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 105 106

Commentaires sur ces manuels

Pas de commentaire