Page 1
SmartSensor 105
Installation and Configuration
I. Connect to sensor
a. Connect the SmartSensor cable to the battery using the positive and negative battery
terminals
b. Connect serial cable from SmartSensor cable to laptop COM port
c. Open the SmartSensor Manager 2.2.5 (SSMPC.07.04.27.exe) on the laptop
d. Connect using the serial connection
II. Modify lane configuration
a. From the “Edit” menu, select “Lane configuration”
b. Toggle mode to “Automatic”
c. Click the “Restart” button:
d. Click OK on the warning that follows
e. Allow at least a few minutes for the SmartSensor to detect vehicles in each lane
Note: The lighter the traffic, the longer it will take for all of the lanes to be detected.
f. To make further adjustments, toggle to “Manual” mode
g. Manual configuration options include:
¾ Adjust Lanes – Adjusts existing lanes by moving shoulder, lane divider, or centerline.
Make sure centerlines (pink lines) are in the center of each driving lane.
¾ Paint Lines –Inserts lane dividers in paved areas
¾ Remove Lines – Removes a lane divider
¾ Remove Lane – Removes one lane of a road
¾ Construct Roads – Inserts a new road consisting of shoulder-center-shoulder
¾ Remove Roads – Removes a road, including all lanes
¾ Construct Barriers – Constructs a median or barrier
¾ Remove Barriers – Removes a median or barrier
¾ Reverse Direction – Reverses the direction of the lane. Initially all the lanes are
shown in the same direction. To display opposing traffic, reverse lane directions.
¾ Edit Lane Names – Labels lane names for later identification of lanes on the Sensor
Info screen.
h. Once all desired lane modifications are made, click Update:
III. Modify data collection parameters
a. From the “Edit” menu, select “Data collection parameters”
b. “General” tab settings:
¾ Sensor (Multi-drop) ID – changes ID number. The default is the last four numbers of
the serial number
¾ RTMS ID – If the user chooses to communicate with the RTMS protocol, all that is
required is the RTMS ID
¾ Description – Creates a description of the SmartSensor
¾ Orientation – Provides a drop-down menu to specify which direction the
SmartSensor is facing. Mainly for benefit of the user
¾ Measurement units – Provides a drop-down menu to specify unit of measurement