e following window will pop up asking you to conrm that you want to restore the sensor
to factory defaults:
Figure 11.7 – Restore to Factory Defaults
e process should take only a few seconds. If it is successful you will see a success message.
Otherwise, you will see a failure message.
Figure 11.8 – Restore Defaults Results
Beam Alignment Tool
Click the Beam Alignment icon to start the Beam Alignment tool (see Figure 11.9). is
tool is used to help the person installing the sensor to visualize the invisible radar beam
footprint, based on the sensor mounting oset and mounting height.
By default, the values in the recommended alignment table (see Appendix D and Table D.1)
are now entered automatically when the Alignment Tool screen rst appears. e align-
ment tool values will be correct only if you have correctly put height and oset information
in the 1. Installation Details screen.
Figure 11.9 – Beam Alignment Tool