66 CHAPTER 6 SENSOR CONFIGURATION
Figure 6.6 – Reboot
If you were in the process of manually editing detection thresholds, it will ask you if you
would like to save these changes to the sensors ash before rebooting (see Figure 6.7). If you
do not save these changes they will be discarded.
Figure 6.7 – Save Changes
During the reboot time, the power button will turn red (see Figure 6.8), but once the sensor
has rebooted it will go back to green again.
Figure 6.8 – Red Button During Reboot
Editing Sensitivity
If missed detections are consistently noticed, the sensor’s sensitivity can be adjusted. De-
creasing the detection threshold levels in areas where trackers begin to disappear will reduce
the number of missed detections. To increase the sensor’s sensitivity, decrease the detection
threshold levels; to decrease the sensor’s sensitivity, increase the detection threshold levels.