58 CHAPTER 5 SENSOR SETTINGS
Figure 5.2 – General Tab
Serial Number – Contains the sensor serial number and can only be edited if you are
in the Advanced Sensor Setup mode (conatct Wavetronix Technical Services for more
information).
Sensor ID – Allows you to enter a multi-drop address for the sensor. e ID default
is the last four digits of the sensor serial number. e sensor ID can be changed, but
no two sensors should have the same ID; the ID must be unique for all sensors on a
multi-drop bus.
Description – Allows you to enter a description for each sensor (i.e. its function, ap-
plication or intended use). Limited to 32 characters.
Location – Allows you to enter the location of the sensor or the approach. Limited to
32 characters.
RF Channel – Displays which radio frequency channel (or non-interference channel)
the device is transmitting on. Using multiple SmartSensor Advance devices in close
proximity will require each one to be set to a dierent RF channel. Similarly, using
multiple SmartSensor Advance Extended Range devices in close proximity will require
each one to be set to a dierent RF channel. However, a SmartSensor Advance device
will not interfere with a SmartSensor Advance Extended Range device, even if they
are on the same RF channel. is is because the hardware used to transmit the Digital
Wave Radar signal is congured dierently on the dierent devices.
Note
It is recommended that the sensor's detection sensitivity be reconfigured after
changing from one RF channel to another.