68 CHAPTER 6 SENSOR CONFIGURATION
3 Click the Edit button and the Edit Sensitivity resholds screen will appear (see Figure
6.10). e following three editing modes are available for modifying sensitivity values:
e +/- mode adds or subtracts the specied number to the existing sensitivity lev-
els.
e % mode sets the sensitivity level to be the specied percent of the existing value.
e Value mode sets the sensitivity level to be the specied value.
Figure 6.10 – Edit Sensitivity Thresholds Screen for Advance (left)
and Advance Extended Range (right)
4 Click and drag again to select the exact range bins to adjust.
5 Make the sensitivity level adjustments.
6 Aer adjusting the sensitivity, click the Enter button to apply the adjustment.
7 Click the OK button to accept the modications and close the Edit Sensitivity window;
click the Undo button to return all modied sensitivity levels to their initial values; or
click the Cancel button to undo all changes made.
8 Re-evaluate the detections.
If any changes were made during the Sensor Conguration process, a pop-up window will
appear prompting the user to save the changes to the sensor’s FLASH memory. Changes
that were not written to FLASH will be lost the next time the sensor reboots. e process of
saving to FLASH memory takes approximately ve seconds.
Selecting a Tracker Display Mode
e following is a list of tracker display data that can be changed by clicking the display bar
at the base of the roadway:
Range
Speed
ETA
ID
Blank
Disabled