CHAPTER 6 SENSOR CONFIGURATION 63
roadway, or by clicking the Stop Bar up/down arrows.
Positioning the Sensor
Position the sensor by clicking on the sensor or its label and dragging it anywhere on the
roadway, or by clicking the Sensor arrow buttons.
e top number, shown in the sensor position display (next to the blue triangle), represents
the sensor’s position to the right or le of the center of the lanes being monitored (Cartesian
x coordinate); the bottom number represents the sensor’s position in front of or behind the
stop bar (Cartesian y coordinate), together forming a Cartesian coordinate pair (x, y). e
sensor’s height is specied by setting the Height value and reects the sensor’s mounting
height above the roadway (Cartesian z coordinate).
e resulting (x, y, z) coordinates describe the sensors position relative to the roadway and
are used to translate the sensor’s native range measurements to range measurements that
are relative to the roadway’s frame of reference. e sensor position is also used in the Beam
Alignment tool (see Tools).
Note
The sensor’s range is updated whenever the stop bar is moved.
Resetting Zones After Sensor Relocation
When the sensor location is changed, existing zones may no longer be within the sensor’s
detection range and the message below will appear (see Figure 6.3):
Figure 6.3 – Sensor Location Changed
It is always recommended to rst position the sensor and then congure detection zones.
However, if the sensor location is modied aer zone conguration, you can do one of the
following:
1 Manually check all detection zones and modify zones as needed (recommended). All
zones will still be available and their location relative to the sensor will be preserved.
If le uncorrected, the zones may no longer perform the desired detection function.
2 Reload only the channel conguration from a backup le created from the existing
conguration (the out-of-range zones will be deleted and the desired detection func-
tions may be compromised).