Wavetronix SMARTSENSOR 105 Guide de l'utilisateur Page 40

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 107
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 39
CHAPTER 3 CONTACT CLOSURE COMMUNICATION 39
menu option.
4 Press and hold the mode switch to cycle through the submenu. e Level 2 LEDs will
light to indicate that the device is cycling though all conguration options.
5 Release the mode switch once the desired conguration option is reached.
6 Quickly press and release the mode switch to select the current conguration option.
e device will exit Menu mode, and either the selected function will run or the se-
lected conguration will be set and saved to the device.
Channel Mapping
Once the Click 104/112/114 devices are installed, make sure that each detector rack chan-
nel is properly mapped to the correct trac phase in the trac controller. e general
NEMA standard for 8-phase numbering is presented in Figure 3.8. Many intersections
will not have eight phases, and in some cases they may not even follow the NEMA conven-
tion. Check the plans in the trac signal cabinet to verify how the phases are numbered at
each intersection.
2
5
1
6
4
7
8
3
Figure 3.11 – Standard NEMA 8-phase Number Scheme
Phases 1, 2, 5 and 6 are often used for the “main street, and phases 3, 4, 7 and 8 are often
used for the side street as shown in Figure 3.8.
Note
Chapter 10 contains a section about Rack Card Tools which explains how the
channel-to-phase mapping can be verified with or without the sensors installed.
Since each Matrix sensor often detects both the left-turn phase and the through-move-
ment phase for a single approach, the associated rack card will have often have channels
that correspond to one of the following phase (ф) pairs: ф2 and ф5; ф6 and ф1; ф4 and ф7;
ф8 and ф3.
Vue de la page 39